VIT-F Laser Cutting Machine

Tube Laser Cutting Machine

VIT-F85 — VIT-F Laser Cutting Machine

VIT-F85 tube application configuration should identify the finished features on every component included in the purchase. A large stock description alone does not convey the work required. Attach the drawings and keep each part linked to its section, material and quantity so the proposal can address a defined set of tube jobs.

VIT-F85 is listed in the VIT-F tube laser cutting range with a 12000*850mm Working Area entry, 12-20kW laser power range and FSCUT control. Preserve the original area label. A specific section geometry, stock length or loading arrangement still needs to be described and addressed in the project response.

Request a quote

[email protected]

Technical specifications

VIT-F85 — technical specifications
SpecificationVIT-F85
Working Area12000*850mm
Positioning Accuracy±0.05 mm
Repositioning Accuracy±0.02 mm
Max Moving Speed100 m/min
Laser SourceMax/IPG
Laser Power12-20kw
Control SystemFSCUT
Machine Size11800*2280*2600mm
Product Weight5000-20000kg
Max Acceleration0.6-1.2G
Voltage220V 1P 50HZ /380V 3P 50HZ

Configuration options vary by model. Confirm the final specification, selected components and operating requirements with your quotation.

Other models in this series

VIT-F85 tube project brief with finished-part features

The VIT-F85 tube project brief should distinguish raw-stock information from finished-part information. For the stock, give section shape, dimensions, wall thickness, material and incoming length. For each part, attach the current drawing, required features and quantity. If several parts share one section, retain their individual drawing references.

VIT-F35 lists Working Area as 12000*350mm compared with 12000*850mm for VIT-F85. Use the comparison as the source labels it. Do not turn the second values into universal tube diameters or assume the field by itself confirms the suitability of every section in the inquiry.

The VIT-F85 table gives ±0.05mm Positioning Accuracy, ±0.02mm Repositioning Accuracy, 100m/min Max Moving Speed and 0.6-1.2G Max Acceleration. Keep the signs and labels when reviewing equipment. These parameters do not state the cutting rate, completed-part tolerance result or handling cycle for the submitted components.

VIT-F85 machine options and the intended work arrangement

VIT-F85 machine options should be discussed with essential features identified on the drawings. Mark any provisional details and separate possible later components from the current purchase. A general model selection should not imply that unfinished or unsubmitted geometry has already been confirmed.

Describe how stock is intended to reach the work area and what handling questions remain unresolved. Ask what arrangement is proposed and which items are included. This is a project-scope discussion, not evidence that a particular loading system, payload or unattended process comes with the machine.

Machine Size is listed as 11800*2280*2600mm, while Product Weight is 5000-20000kg. Ask for the exact dimensions and equipment weight of the offered configuration before using them in a layout discussion. The weight range must not be repurposed as a permissible tube load or as a confirmed value for every option.

VIT-F85 quotation requirements for the actual configuration

VIT-F85 quotation requirements should name the selected power within 12-20kW and the proposed Max or IPG laser source. FSCUT is the stated control. Keep these choices beside the current component list so a later rating or source change is not confused with a change in the workpiece requirements.

The source lists voltage alternatives of 220V 1P 50HZ and 380V 3P 50HZ. Provide the actual destination supply and request confirmation of the offered configuration and installation requirements. Do not infer that both supplies can be used automatically from their appearance in one table row.

Request a supplied-item list and overall equipment layout with the offer, and retain all unanswered application questions. Use the series and comparison-model links to review the published fields. Send the contact page the complete stock and drawing records, including any feature or handling issues that need a specific response.

Product questions

Why give each part its own drawing reference?

Different components may share raw stock but require different finished features and quantities. Keep those differences visible in the application record.

Does 850mm establish every allowable tube section?

The source calls the field Working Area. Describe the actual section and ask how the proposed arrangement addresses it rather than assuming an unrestricted section limit.

What is different in the VIT-F35 field?

Working Area is listed as 12000*350mm rather than 12000*850mm. The comparison does not itself confirm a stock-loading arrangement.

Is 5000-20000kg a material-load specification?

It is labelled Product Weight. Ask for the exact equipment weight of the proposal and discuss the intended tube stock separately.

What electrical information belongs in the inquiry?

Provide the destination supply and confirm the selected voltage configuration. The listed alternatives do not establish automatic operation on both supplies.

Related equipment and information

Compare VIT-F Laser Cutting Machine models

Compare VIT-F35

Discuss your drawing and configuration

Published product reference

Ready to discuss VIT-F85?

Share your material, dimensions and process. Start a conversation about the right configuration.

Request a quote